HSF-A MODEL TABLE: 300W
|
MODEL
|
OUTPUT VOLTS (V d-c)
|
ADJUSTMENT RANGE(1)(2) (V d-c)
|
OVP SETTING(4) (V d-c)
|
OUTPUT CURRENT(5) (A d-c) 0-40°C
|
OVERCURRENT SETTING(6) (A d-c)
|
MAXIMUM RIPPLE & NOISE(7) (mV p-p)
|
External Resistance or Voltage
|
Front Panel Trimpot
|
Minimum Adjustment(3)
|
300 WATT MODELS (Suffix A, AM)
|
HSF 5-60A, AM |
5 |
0 - 5.5 |
0 - 5.5 (8) |
4.5 (9) |
5.75 - 6.75 |
60 |
63 (10) |
120/180 (11) |
HSF 12-27A, AM |
12 |
0 - 13.8 |
0 - 13.8 (8) |
6 |
14.5 - 16.9 |
27 |
28.4 (10) |
150/200 (11) |
HSF 15-22A, AM |
15 |
0 - 17.4 |
0 - 17.4 (8) |
7 |
18.3 - 21.3 |
22 |
23.1 (10) |
150/200 (11) |
HSF 24-14A, AM |
24 |
0 - 28.2 |
0 - 28.2 (8) |
7 |
29.5 - 34.3 |
14 |
16.7 (10) |
150/200 (11) |
HSF 28-12A, AM |
28 |
0 - 29 |
0 - 29 (8) |
7 |
29.5 - 34.3 |
12 |
16.7 (10) |
150/200 (11) |
HSF 48-7A, AM |
48 |
0 - 52.2 |
0 - 52.2 (8) |
7 |
54.7 - 63.9 |
7 |
7.4 (10) |
350/400 (11) |
(1) |
Using trimpot to attain voltages outside the specified adjustment range may trigger undervoltage or overvoltage faults.
|
(2) |
0V is approximate (logic 0: 0.0 - 0.4V d-c).
|
(3) |
Observe minimum for proper functioning of alarm relay, optional meter and LED. Models with Z suffix do not require a minimum adjustment for proper functioning of alarm relay, optional meter and LED.
|
(4) |
When undervoltage or overvoltage is detected, output is shut OFF. Recovery is either by opening, then reconnecting, short across ±RC terminals (no delay), or by removing, and after approximately 40 seconds, reapplying a-c input power.
|
(5) |
See Power vs. Temperature for power derating.
|
(6) |
Constant current limit with automatic recovery, except 5V model: constant current limit with hiccup and automatic recovery.
|
(7) |
Measure with JEITA RC-9131A probe, bandwidth of scope: 100MHz.
|
(8) |
Internal DIP SW 1, position 7, controls front panel adjustment range: ON allows adjustment down to zero, OFF allows adjustment down to approximate Minimum Adjustment value.
|
(9) |
For model HSF 5-60AM, 3V d-c minimum output is required for VDC ON/ALARM indicator to function, no minimum required
for alarm relay and meter to function. VDC ON/ALARM indicator brightness is dimmer than other models (this is normal).
|
(10) |
Current Limit setting.
|
(11) |
0°C ≤ 70°C/-10°C ≤ 0°C
|
|