HSF-A MODEL TABLE: 600W
|
MODEL
|
OUTPUT VOLTS (V d-c)
|
ADJUSTMENT RANGE(1)(2) (V d-c)
|
OVP SETTING(4) (V d-c)
|
OUTPUT CURRENT(5) (A d-c) 0-40°C
|
OVERCURRENT SETTING(6) (A d-c)
|
MAXIMUM RIPPLE & NOISE(7) (mV p-p)
|
External Resistance or Voltage
|
Front Panel Trimpot
|
Minimum Adjustment(3)
|
600 WATT MODELS (Suffix A, AM)
|
HSF 12-53A, AM |
12 |
0 - 13.8 |
0 - 13.8 (8) |
6 |
14.5 - 16.9 |
53 |
55.1 (9) |
150/200 (10) |
HSF 15-43A, AM |
15 |
0 - 17.4 |
0 - 17.4 (8) |
7 |
18.2 - 21.8 |
43 |
45.1 (9) |
150/200 (10) |
HSF 24-27A, AM |
24 |
0 - 28.2 |
0 - 28.2 (8) |
7 |
29.5 - 34.3 |
27 |
28.3 (9) |
150/200 (10) |
HSF 28-23A, AM |
28 |
0 - 29 |
0 - 29 (8) |
7 |
29.5 - 34.3 |
23 |
28.3 (9) |
150/200 (10) |
HSF 48-13A, AM |
48 |
0 - 52.2 |
0 - 52.2 (8) |
7 |
54.8 - 64.3 |
13 |
13.6 (9) |
350/400 (10) |
(1) |
Using trimpot to attain voltages outside the specified adjustment range may trigger undervoltage or overvoltage faults.
|
(2) |
0V is approximate (logic 0: 0.0 - 0.4V d-c).
|
(3) |
Observe minimum for proper functioning of alarm relay, optional meter and LED. Models with Z suffix do not require a minimum adjustment for proper functioning of alarm relay, optional meter and LED.
|
(4) |
When undervoltage or overvoltage is detected, output is shut OFF. Recovery is either by opening, then reconnecting, short across ±RC terminals (no delay), or by removing, and after approximately 40 seconds, reapplying a-c input power.
|
(5) |
See Power vs. Temperature for power derating.
|
(6) |
Constant current limit with automatic recovery.
|
(7) |
Ripple and Noise specifications are 1.5 times indicated values for temperature range of -10°C to 0°C. Ripple and noise levels above are satisfied when conditions are 0 to 100% load, 0 to 55°C (see Power vs. Temperature for power derating between 40°C and 55°C) and bandwidth ≤ 100 MHz.
|
(8) |
Internal DIP SW 1, position 7, controls front panel adjustment range: ON allows adjustment down to zero, OFF allows adjustment down to approximate Minimum Adjustment value.
|
(9) |
Current Limit setting.
|
(10) |
0°C ≤ 70°C/-10°C ≤ 0°C
|
|