Follow @kepco_careers
Advanced Search
Kepco Power Solutions
718-461-7000
 
HSF 300W/600W/1200W/1500W Metered Photo HSF 300W/600W/1200W/1500W in rack Photo
   HSF-A MODEL TABLE: 600W
MODEL OUTPUT
VOLTS
(V d-c)
ADJUSTMENT RANGE(1)(2)
(V d-c)
OVP
SETTING(4)
(V d-c)
OUTPUT
CURRENT(5)
(A d-c)
0-40°C
OVERCURRENT
SETTING(6)
(A d-c)
MAXIMUM
RIPPLE &
NOISE(7)
(mV p-p)
External Resistance
or Voltage
Front Panel
Trimpot
Minimum
Adjustment(3)
600 WATT MODELS (Suffix A, AM)
HSF 12-53A, AM 12 0 - 13.8 0 - 13.8 (8) 6 14.5 - 16.9 53 55.1 (9) 150/200 (10)
HSF 15-43A, AM 15 0 - 17.4 0 - 17.4 (8) 7 18.2 - 21.8 43 45.1 (9) 150/200 (10)
HSF 24-27A, AM 24 0 - 28.2 0 - 28.2 (8) 7 29.5 - 34.3 27 28.3 (9) 150/200 (10)
HSF 28-23A, AM 28 0 - 29 0 - 29 (8) 7 29.5 - 34.3 23 28.3 (9) 150/200 (10)
HSF 48-13A, AM 48 0 - 52.2 0 - 52.2 (8) 7 54.8 - 64.3 13 13.6 (9) 350/400 (10)
(1) Using trimpot to attain voltages outside the specified adjustment range may trigger undervoltage or overvoltage faults.
(2) 0V is approximate (logic 0: 0.0 - 0.4V d-c).
(3) Observe minimum for proper functioning of alarm relay, optional meter and LED. Models with Z suffix do not require a minimum adjustment for proper functioning of alarm relay, optional meter and LED.
(4) When undervoltage or overvoltage is detected, output is shut OFF. Recovery is either by opening, then reconnecting, short across ±RC terminals (no delay), or by removing, and after approximately 40 seconds, reapplying a-c input power.
(5) See Power vs. Temperature for power derating.
(6) Constant current limit with automatic recovery.
(7) Ripple and Noise specifications are 1.5 times indicated values for temperature range of -10°C to 0°C. Ripple and noise levels above are satisfied when conditions are 0 to 100% load, 0 to 55°C (see Power vs. Temperature for power derating between 40°C and 55°C) and bandwidth ≤ 100 MHz.
(8) Internal DIP SW 1, position 7, controls front panel adjustment range: ON allows adjustment down to zero, OFF allows adjustment down to approximate Minimum Adjustment value.
(9) Current Limit setting.
(10) 0°C ≤ 70°C/-10°C ≤ 0°C